Heating And Cooling Chiller

You are Here: Product / Air Cooled Chiller / Heating And Cooling Chiller /

Heating And Cooling Chiller

Heating and cooling chiller unit 7kw to 42kw
  • Heating And Cooling Chiller
  • Brand:HERO-TECH
  • Model:HTHC-3A,HTHC-5A,HTHC-8AD,HTHC-10AD,HTHC-15AD
  • Type:Air-Cooled
  • Certification:CE, Other
  • Cooling Capability(kw):7kw to 50kw
  • Update Time:03/06/2013
Detailed Info

Heating and cooling chiller unit

Features

Temperature control is between 5~50C with an accuracy of ±1C.
Stainless iron insulated water tank.
Adopts imported compressor.
Anti-icing protection, over-temperature protection.
R22 is employed as refrigerant, refrigeration effect is favorable.
Refrigeration return circuit is controlled by high and low pressure switches.
Overload protection is adopted for compressor and pump.
Shell-tube styled cooler is adopted due to its excellent heat transfer and dissipation. 
Plate-type evaporator has a small size, occupying a small space.
Simple operation and structure render maintenance easy.
high COP:2.73--2.99

Parameter table

model HTHC-3A HTHC-4A HTHC-5A HTHC-6A HTHC-8AD HTHC-10AD HTHC-12AD HTHC-15AD
nominal cooling capacity kw 7.91 12.15 12.9 15.22 20.47 25.8 30.8 41.8
heating power Kw 6 9 9 12 12 18 18 24
max power consumption Kw 9.57 13.17 14.68 18.28 20.25 29.5 30.9 34.42
full load Amp 23.2 32 35.6 44.6 49.2 71.6 75 100.6
power source   3PH  380V-415V  50HZ
refrigerant type   R22
control   thermostatic expansion valve
compressor type   hermetic scroll
power kw 2.9 3.5 4.55 5.25 3.5*2 4.55*2 5.25*2 7*2
fan information air flow m3/h 3000 4000 5000 6000 8000 10000 12000 15000
motor kw 0.15*2 0.15*2 0.19*2 0.19*2 0.25*2 0.45*2 0.45*2 0.6*2
condenser type   finned copper tube + low noise outer rotor fan
evaporator type   copper coil built-in storage tank
coolant flow m3/h 1.36 2.09 2.22 2.6 3.52 4.44 5.03 7.1
tank volume liter 50 60 60 110 120 200 200 270
inlet and outlet inch 1 1 1 1 1-1/2 1-1/2 2 2
safety devices   inner thermostat for compressor motor, over-current, high and low pressure switch, three phase protection relay, low level switch, freeze protection thermostat
dimension length mm 980 980 1120 1120 1300 1500 1500 1780
width mm 560 560 610 610 680 760 760 800
height mm 1320 1320 1390 1390 1530 1660 1660 1800
weight

kg

135 150 170 190 280 360 400 600
Remarks:
1. norminal cooling capacity according to:
coolant inlet inlet 7C, outlet 12C, temperature difference from 3C to 8C;
cooling air inlet 30C, outlet 38C;
2. chiller should be used under 40C ambient temperature;
3. Specification, appearances and dimensions are subject to change without notice.